1.Specifications | Â | Â | Â | Â | Â | Â | Â | Â |
 | Rated | poles | Rated insulating voltage(V) |
Rated operating voltage(V) |
Ultimate short circuit breaking capacity (kA) |
Servies short circuit  breakering capacity (KA) |
Operation life (times) |
|
Type | current(A) | Â | ||||||
 |  |  | Electrical Mechanical | |||||
(mm) | Â | Â | Â | Â | Â | Â | Â | Â |
LNSX-100D | 12.5,16,20,25,32, 40,50,63,80,100 |
3,4 | 950 | 690 | 18 | 18 | 1500 | 8500 |
LNSX-100N | 25 | 25 | ||||||
LNSX-100H | 70 | 70 | ||||||
LNSX-100L | 150 | 150 | ||||||
LNSX-160D | 16,20,25,32, 40,50,63,80,90 |
25 | 25 | 1000 | 7000 | |||
LNSX-160N | 36 | 36 | ||||||
LNSX-160H | 70 | 70 | ||||||
LNSX-160L | 150 | 150 | ||||||
LNSX-250D | 160,180,200 225,250 |
25 | 25 | 1000 | 7000 | |||
LNSX-250N | 36 | 36 | ||||||
LNSX-250H | 70 | 70 | ||||||
LNSX-250L | 150 | 150 | ||||||
LNSX-400D | 200,225, 250,300,315,400 |
35 | 35 | 1000 | 4000 | |||
LNSX-400N | 45 | 45 | ||||||
LNSX-400H | 70 | 70 | ||||||
LNSX-400L | 150 | 150 | ||||||
LNSX-630D | 315,350,400 500,600,630 |
35 | 35 | 1000 | 4000 | |||
LNSX-630N | 45 | 45 | ||||||
LNSX-630H | 70 | 70 | ||||||
LNSX-630L | 150 | 150 |
EPS basic working principle similar to the backup UPS or inverter, that is, when the electricity is normal, the electricity through the EPS mains bypass directly to the load, when the utility power, EPS switch to the battery inverter power supply to the load. Applicable to emergency panel lights and the like, you can adjust the control current to reach the emergency control of the voltage, control energy.
For most in the lighting industry industry there is a very real learning curve as we explore the intricacies, applications, limitations and potential of this amazing light source. Despite the curve, use of LED lighting for general lighting purposes is rapidly growing. Its popularity is not a mystery. LED technology is continually
improving. LEDs offer long life and high efficiency, have low operating costs and are lead and mercury free.
As with other types of lighting, LED lighting must meet the life safety code requirements for emergency illumination. LED fixtures serving as emergency units
must, therefore, provide at least 90 minutes of emergency lighting. Philips Bodine emergency LED drivers and emergency lighting inverters allow these fixtures
to meet or exceed code.