When an inverter is integrated with an automatic control system, it's important to recognize the differences between how the inverter and a regulating valve operate, which can lead to certain challenges that require careful consideration. First and foremost, when providing the frequency signal, it’s advisable to use the internationally recognized 4-20 mA standard signal whenever possible. Ensure proper shielding and grounding of the signal lines to prevent interference from affecting the inverter. Interference is common in industrial settings, and it can destabilize the control system. Thus, enabling the input filter is crucial, with a setting range of 0.00-5.00 seconds. If the inverter’s built-in PID function is utilized, consider activating the feedback filter to enhance the stability of the PID control, with a setting range of 0.0-60 seconds. However, note that if the filter time is excessively long, the system may become overly stable but sluggish in responding; conversely, if it’s too short, the system might respond quickly but become unstable. Therefore, adjust the filter time based on the specific conditions at the site.
Secondly, configure the appropriate manual and automatic switching operations. The Communicator offers manual, automatic, and forced manual modes. Depending on requirements, consider implementing redundant current and voltage frequency setting options. This means that during normal operation, the inverter’s frequency is set via current, while in abnormal conditions, voltage can be used instead—this involves adding a potentiometer to manually set the inverter’s frequency. With both current and voltage signals serving as inputs, the system’s redundancy is significantly enhanced.
Thirdly, always activate the “inspection switch,†or the “on-site maintenance switch,†located near the rotating machinery. When this switch is toggled to the “inspection†mode, it effectively disconnects the inverter’s running signal loop, preventing accidental activation of the equipment during maintenance. This ensures the safety of maintenance personnel working on the machinery.
Leverage the inverter’s input and output control terminal functions to implement alarm and interlock features, which simplifies wiring and improves overall reliability. For simpler systems or standalone machines, the inverter’s built-in PID control function can be fully utilized to minimize required equipment and reduce costs.
Lastly, some inverters include control power input terminals labeled R0 and T0. It’s essential to connect the control power to these terminals prior to energizing the main power supply. This ensures that the inverter retains its display functionality even when tripped, allowing operators to diagnose faults and take corrective actions more effectively.
In conclusion, integrating an inverter with an automated system requires a comprehensive understanding of potential challenges and solutions. By carefully addressing these aspects, you can optimize performance, enhance safety, and reduce costs in your application.